3. ALIGNMENT FOR AM TUNING VOLTAGE RANGE
a. Required Instruments:
DVM
b. Alignment Procedure
Mode Adjustment Procedure
(1) Turn on the radio.
(2) Connect the probe of DVM to the test point TP2 and TP3.
(3) Tune the AM frequency to 522KHz.
(4) Adjust L4 to have a reading of 1.2 ± 0.04V.
(5) Tune the AM frequency to 1629KHz.
AM
L4
TC3
(6) Adjust TC3 to have a reading of 6.5 ± 0.3V.
c. Instrument Connection
TC3
L4
TP2
TP3
DVM